Osburn Matrix Wood Stove W/Blower

OB02032

Status: In Stock

US$3,399.00

Description

Description

*Pricing reflects additional freight costs to Alaska.

Introducing the Osburn Matrix Wood Stove with Blower, a versatile heating solution designed to bring warmth and style to various spaces. This high-performance wood stove is perfect for medium to large-sized applications, including living rooms, cabins, and even small commercial areas.

With its sleek and modern design, the Osburn Matrix Wood Stove adds a touch of sophistication to any space. Its recommended heating area of up to 2,100 square feet makes it suitable for a range of room sizes and layouts. Whether you want to cozy up your living room or provide efficient heating for a cabin retreat, the Matrix Wood Stove delivers.

Equipped with a powerful blower, this stove ensures optimal heat distribution throughout your space, reaching every corner with ease. The blower enhances heat circulation, allowing for faster and more even warming of your environment.

Featuring a firebox volume of 2.4 cubic feet, the Matrix Wood Stove can accommodate larger logs, enabling longer burn times. With a maximum heat output of 75,000 BTU/h (22.0 kW), this stove provides substantial warmth to keep you comfortable during colder seasons.

The Matrix Wood Stove prioritizes efficiency, with an average overall efficiency of 72% (HHV) and 77% (LHV). Its low average particulate emissions rate of 2.3 g/h and average CO emissions of 69 g/h make it an environmentally-conscious choice.

Upgrade your heating system with the Osburn Matrix Wood Stove with Blower and experience the perfect blend of performance and style. Enjoy the warmth and comfort it brings while adding a modern focal point to your space.

A Tax Credit is available for this product!

Required Accessories:

Requires the addition of one each of (A) and (B) required accessories to complete the unit

A:

  • OA10700  Black Side Panels Kit
  • OA10701  Soapstone Side Panels Kit

B:

  • OA10703  Soapstone Panel Top
  • OA10704  Black Panel Top

Features

Features

  • Fuel type: Dry cordwood
  • Recommended heating area (sq. ft.): 500 - 2,100
  • Overall firebox volume: 2.4
  • EPA loading volume (cu. ft.): 2.02
  • Maximum burn time: 8 h
  • Maximum heat output (dry cordwood): 75,000 BTU/h (22.0 kW)
  • Overall heat output rate (min. to max.): 14,800 BTU/h (4.34 kW) to 28,600 BTU/h (8.38 kW)
  • Average overall efficiency (EPA cribs/Douglas fir): N.A. (HHV) N.A. (LHV)
  • Average overall efficiency (dry cordwood): 69% (HHV) 74% (LHV)
  • Optimum efficiency: 77%
  • Average particulate emissions rate: 1.54 g/h
  • Average CO: 89.4 g/h

Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

(Average Overall Efficiency) As measured per CSA B415.1-10 stack loss method.

(HHV) Higher Heating Value of the fuel.

(LHV) Lower Heating Value of the fuel.

Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

Optimum overall efficiency at a specific burn rate (LHV).

This appliance is officially tested and certified by an independent agency.

Specifications

Specifications

Combustion technology: Non-catalytic
High-efficiency certified appliance: Yes, EPA 2020 approved
Maximum log length: 20"
Log positioning: Over width
Chimney diameter: 6"
Flue outlet diameter: 6"
Type of chimney: CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet): 12'
Baffle type: C-Cast
Approved for an alcove installation: Yes
Approved for a mobile home installation: Yes, with fresh air intake
Shipping Weight: 506 lb (230 kg)
Door type: Single, glass with cast iron frame
Glass type: Ceramic glass
Glass surface – dimensions (Width X Height): 19 5/8" x 11 7/8"
Glass air-wash system: Yes
Premium quality blower included (CFM): 130
Overall dimension (Height): 36 7/8"
Overall dimension (Width): 27 1/8"
Overall dimension (Depth): 25"
Door opening – dimension (Height): 8 3/4"
Door opening - dimension (Width): 17 1/2"
Firebox – dimension (Height): 11 7/8"
Firebox – dimension (Width): 21"
Firebox – dimension (Depth): 16 1/2"
Firebox lined with refractory bricks for better heat distribution: Yes
Stainless-steel secondary-air system improving gas combustion: Yes
Model: Pedestal
Steel thickness – body: 3/16"
Steel thickness – top: 5/16"
USA standard (emissions): EPA
Canadian Standard (emissions): CSA B415.1-10
USA standard (safety): UL 1482, UL 737
Canadian standard (safety): ULC-S627
Tested and listed as per applicable standards: By an accredited laboratory (CAN/USA)
Warranty: Limited lifetime

 

Minimum clearances to combustibles* 
(Data expressed in inches. 1 inch = 25.4 mm)

                                                                                    Canada                     USA

  Single wall pipe

Double wall pipe

Single wall pipe Double wall pipe
Clearance – back wall 14 1/2" 6" 11" 6"
Clearance - corner 10" 7" 10" 7"
Clearance – side wall 17" 17" 16" 16"
Clearance – top (measured from the platform on which the appliance is installed)** 84" 84" 84" 84"
Clearance – minimum floor protection in front of the appliance 18"   18"  

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.